Distinguishing Persistent Failures from Transient Losses - Université Pierre et Marie Curie Accéder directement au contenu
Communication Dans Un Congrès Année : 2008

Distinguishing Persistent Failures from Transient Losses

Italo Cunha
  • Fonction : Auteur
  • PersonId : 980397
Renata Teixeira
Nick Feamster
  • Fonction : Auteur
Christophe Diot
  • Fonction : Auteur

Résumé

Network tomography is a promising technique to identify the location of of IP faults. The goal of tomography is to infer the status of network internal characteristics based on end-to-end observations. In particular, binary tomography identifies the set of failed links from end-to-end path meausrments. Upon detecting the failure of one or more of the monitored paths, a monitor sends its measurements to a central coordinator. The coordinator then runs the binary tomography algorithm, which takes as input the topology of the network and the status (i.e., up or down) of all monitored paths and finds the minimum set of links that explain the observations.
Fichier non déposé

Dates et versions

hal-01303779 , version 1 (18-04-2016)

Identifiants

Citer

Italo Cunha, Renata Teixeira, Nick Feamster, Christophe Diot. Distinguishing Persistent Failures from Transient Losses. The 4th ACM International Conference on emerging Networking EXperiments and Technologies (ACM CoNEXT 2008), Dec 2008, Madrid, Spain. pp.50, ⟨10.1145/1544012.1544062⟩. ⟨hal-01303779⟩