Validation of the IASI FORLI/EUMETSAT ozone products using satellite (GOME-2), ground-based (Brewer–Dobson, SAOZ, FTIR) and ozonesonde measurements - Université Pierre et Marie Curie Accéder directement au contenu
Article Dans Une Revue Atmospheric Measurement Techniques Année : 2018

Validation of the IASI FORLI/EUMETSAT ozone products using satellite (GOME-2), ground-based (Brewer–Dobson, SAOZ, FTIR) and ozonesonde measurements

Anne Boynard
  • Fonction : Auteur
  • PersonId : 938803
Florence Goutail
Juliette Hadji-Lazaro
  • Fonction : Auteur
  • PersonId : 915259
Jean-Pierre Pommereau
Andrea Pazmino
  • Fonction : Auteur
  • PersonId : 968970

Résumé

This paper assesses the quality of IASI (Infrared Atmospheric Sounding Interferometer)/Metop-A (IASI-A) and IASI/Metop-B (IASI-B) ozone (O3) products (total and partial O3 columns) retrieved with the Fast Optimal Retrievals on Layers for IASI Ozone (FORLI-O3; v20151001) software for 9 years (2008–July 2017) through an extensive intercomparison and validation exercise using independent observations (satellite, ground-based and ozonesonde). Compared with the previous version of FORLI-O3 (v20140922), several improvements have been introduced in FORLI-O3 v20151001, including absorbance look-up tables recalculated to cover a larger spectral range, with additional numerical corrections. This leads to a change of  ∼ 4% in the total ozone column (TOC) product, which is mainly associated with a decrease in the retrieved O3 concentration in the middle stratosphere (above 30hPa/25km). IASI-A and IASI-B TOCs are consistent, with a global mean difference of less than 0.3% for both daytime and nighttime measurements; IASI-A is slightly higher than IASI-B. A global difference of less than 2.4% is found for the tropospheric (TROPO) O3 column product (IASI-A is lower than IASI-B), which is partly due to a temporary issue related to the IASI-A viewing angle in 2015. Our validation shows that IASI-A and IASI-B TOCs are consistent with GOME-2 (Global Ozone Monitoring Experiment-2), Dobson, Brewer, SAOZ (Système d'Analyse par Observation Zénithale) and FTIR (Fourier transform infrared) TOCs, with global mean differences in the range of 0.1%–2% depending on the instruments compared. The worst agreement with UV–vis retrieved TOC (satellite and ground) is found at the southern high latitudes. The IASI-A and ground-based TOC comparison for the period from 2008 to July 2017 shows the long-term stability of IASI-A, with insignificant or small negative drifts of 1%–3%decade−1. The comparison results of IASI-A and IASI-B against smoothed FTIR and ozonesonde partial O3 columns vary with altitude and latitude, with the maximum standard deviation being seen for the 300–150hPa column (20%–40%) due to strong ozone variability and large total retrievals errors. Compared with ozonesonde data, the IASI-A and IASI-B O3 TROPO column (defined as the column between the surface and 300hPa) is positively biased in the high latitudes (4%–5%) and negatively biased in the midlatitudes and tropics (11%–13% and 16%–19%, respectively). The IASI-A-to-ozonesonde TROPO comparison for the period from 2008 to 2016 shows a significant negative drift in the Northern Hemisphere of −8.6±3.4%decade−1, which is also found in the IASI-A-to-FTIR TROPO comparison. When considering the period from 2011 to 2016, the drift value for the TROPO column decreases and becomes statistically insignificant. The observed negative drifts of the IASI-A TROPO O3 product (8%–16%decade−1) over the 2008–2017 period might be taken into consideration when deriving trends from this product and this time period.
Fichier principal
Vignette du fichier
amt-11-5125-2018.pdf (15.28 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

insu-01876951 , version 1 (31-01-2020)

Identifiants

Citer

Anne Boynard, Daniel Hurtmans, Katerina Garane, Florence Goutail, Juliette Hadji-Lazaro, et al.. Validation of the IASI FORLI/EUMETSAT ozone products using satellite (GOME-2), ground-based (Brewer–Dobson, SAOZ, FTIR) and ozonesonde measurements. Atmospheric Measurement Techniques, 2018, 11 (9), pp.5125 - 5152. ⟨10.5194/amt-11-5125-2018⟩. ⟨insu-01876951⟩
200 Consultations
41 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More