Analysis of Fractured Samples with Digital Volume Correlation - Université Pierre et Marie Curie Accéder directement au contenu
Communication Dans Un Congrès Année : 2013

Analysis of Fractured Samples with Digital Volume Correlation

Résumé

Synchrotron X-ray tomography was used to monitor in situ three dimensional (3D) fatigue crack propagation in a nodular graphite cast iron. Direct image analysis allows for the retrieval of the successive positions of the crack front, and the detection of local crack retardation, while volume correlation enables for the measurement of displacement fields in the bulk of the specimen. Stress Intensity Factors (SIF) are extracted from the measured displacement fields. It is possible to link the non propagation of a crack with crack closure in COD maps or with a local value of the measured SIF range.
Fichier principal
Vignette du fichier
Hild2013.pdf (205.22 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-01668796 , version 1 (27-04-2021)

Licence

Paternité

Identifiants

Citer

François Hild, Jean-Yves Buffière, Anthony Gravouil, Nathalie Limodin, Julien Réthoré, et al.. Analysis of Fractured Samples with Digital Volume Correlation. Annual Conference on Experimental and Applied Mechanics, Jun 2010, Indianapolis, United States. pp.327-330, ⟨10.1007/978-1-4419-9796-8_42⟩. ⟨hal-01668796⟩
119 Consultations
65 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More